Standard checklist - flow meter support

Standard checklist - flow meter support

This list of questions is essential to provide the right support. It helps us to be of quicker assistance, as we have a complete picture of the situation.

Process:
  • Inner Diameter of the pipe
  • Upstream length
  • Downstream length
  • Average pressure in the system
  • Min, max, average flow
  • Min, max, average temperature
  • Air/gas quality; wet or dry
Location:
  • P & ID or sketch of the installation
  • Photo environment, with the flow meter on it, to check the location and the surroundings
  • Inside or outside location, if outside is it exposed to sun/ rain etc?
  • How in the tube: Veritcal, horizontal installation?
    • In vertical pipe: rising or falling flow?
    • In horizontal pipe: is it at two o' clock or is it mounted at the top, or bottom?
Signals:
  • What output is used: Display, 4 ... 20 mA, RS485, Ethernet? Data logger?
    • if 4.. 20 mA: do the math by hand, check if the output signal in mA corresponds with the measured value, and the 4 .. 20 mA max/ min settings
    • If RS485: Do you experience communication problems? Did you check power supply at the meter? Is it at least 14 Volt ?
    • If data logger present: Data log file available? Please send the file (CSV)
Please collect this information so we can be of further assistance.
    • Related Articles

    • Compressed air flow meters - how to minimize installation errors

      So you are measuring compressed air flow? Great! Now you can generate some serious savings. But wait! You have installed three meters downstream of a main flow meter, and you add them all up? and you see that the sum of these is not equal to the main ...
    • Site visit preparation checklist

      SECURITY CHECK Check safety and personal protection gear. ALWAYS. Eye protection Ear protection Hard Hat Safety Boots Reflective vest Required Permits, Diplomas, Certification for work Equipment list Flowmeters: FlowScope dP with display FlowScope M ...
    • Unreadable fields in VPStudio

      Depending on the computer and also the resolution that is being used, there can be some unreadable fields or tabs within VPStudio 1.25 Solution To solve this issue and make the software functional, below steps should be taken: Right-click on the icon ...
    • Modbus communication with probe probeDP and inline

      The Flowscope probe sensors and inlines have a not very complete implementation of the modbus protocol. This is due to hardware limitations, and is also one of the reasons they are superseded by the flowscopeM line. What is supported Function code 3 ...
    • Byteorder problems

      Legacy flowmeters have their byteorder set at compile time. This means that to change it you will need to get a custom firmware. This situation is not ideal, and should be avoided where possible ( for insctance if the bms has an option for ...